pab gonio-photometer

sample data, reflective materials

Note: BSDF data on this page is outdated. Please refer to our BME website for current data.
name

type
incident angle ϑin, (φin=0)
datapoints, scanmethode
photo measured data
BSDF * cos(ϑout)
visualization of reflection, (log scale) dataset
polar false color plot oblique view
scan methods:
full continous, high speed, interleaved, full scan of sphere (reflective and transmissive side)
inplane continous, high speed scan close to scattering plane (typically ±20°)
peak continous spiral scan around reflected or transmitted peak, very high angular resolution
light sources and detectors:
xenon collimated Osram Xenon-short-arc lamp, Silicon Sensor with Schott BG18 filter
halogen collimated Osram halogen lamp, Silicon Sensor with Schott BG38 filter
laser-green collimated green diodelaser, λ=532nm, Silicon Sensor
laser-red collimated red diodelaser, λ=650nm, Silicon Sensor
format of demodata:
comment lines start with '#'. Each line represents one measured point on the sphere and contains three values: ϑout, φout, value.
Angles are given in [deg] measured from the surface normal (ϑout) and an orientation on the surface (φout). Data values are in arbitrary units if not specified otherwise.
Files contain out-of-the-box measured data without further processing or editing.
aluminium reflectors
alanod-1200c

anodized aluminium
ϑin = 30°
60836, full, halogen
alu/dscn3604-alanod-1200.mini.jpg|
-+
alu/pab-alanod-1200c-30.ortho-log-refl.mini.jpg|
-+
alu/pab-alanod-1200c-30.persp-log-refl.mini.jpg|
-+
pab-alanod-1200c-30.pub.zip
alanod-1100G

anodized aluminium
ϑin = 30°
67569, inplane, halogen
alu/dscn3603-alanod-1100g.mini.jpg|
-+
alu/pab-alanod-1100G-d-30.ortho-log-refl.mini.jpg|
-+
alu/pab-alanod-1100G-d-30.persp-log-refl.mini.jpg|
-+
pab-alanod-1100G-d-30.pub.zip
alanod-miro8-5100

anodized aluminium
ϑin = 30°
60364, peak, laser-green
alu/dscn3602-miro8-5100.mini.jpg|
-+
alu/pab-miro8-5100-30.ortho-log-refl.mini.jpg|
-+
alu/pab-miro8-5100-30.persp-log-refl.mini.jpg|
-+
pab-miro8-5100-30.pub.zip
wall paint
unknown manufact.

waterbased TiO2/chalk wall paint
ϑin = 30°
59419, full, halogen
-
paint/pab-wallpaper-white-a-30.ortho-log-refl.mini.jpg|
-+
paint/pab-wallpaper-white-a-30.persp-log-refl.mini.jpg|
-+
pab-wallpaper-white-a-30.pub.zip

go to: transmission demo data, LED demo data, back to gonio-photometer page


web address of this page: http://pab-opto.de?d=/gonio-photometer/demodata/materials
Datenschutzerklärung , Impressum
page contents © pab

Dr. Peter Apian-Bennewitz, pab-opto